GE Profile
Lighting Circuit Failure
Refrigerator lights not working but unit cools normally.
Advertisements
Possible Causes
Burned-out LED module or bulb, Faulty door switch, Loose light harness connector, Failed main control light driver
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator before replacing light modules.
- Check door switch: Press the door switch; if fans respond but lights do not, the switch is likely good.
- Replace module: On GE Profile LED models, replace the entire LED light module if it is dim or out.
- Inspect connectors: Ensure the light module connector is fully seated.
- Control board: If multiple lights are out and modules test good, the main control board may not be supplying voltage to the lighting circuit.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
LED Light Module
Check Price on Amazon
We may earn a commission from links on this page.