GE Profile Lighting Circuit Failure

Refrigerator lights not working but unit cools normally.

Advertisements

Possible Causes

Burned-out LED module or bulb, Faulty door switch, Loose light harness connector, Failed main control light driver

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before replacing light modules.

  • Check door switch: Press the door switch; if fans respond but lights do not, the switch is likely good.
  • Replace module: On GE Profile LED models, replace the entire LED light module if it is dim or out.
  • Inspect connectors: Ensure the light module connector is fully seated.
  • Control board: If multiple lights are out and modules test good, the main control board may not be supplying voltage to the lighting circuit.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

LED Light Module