GE Profile Temperature Control or Thermistor Miscalibration

Refrigerator runs constantly and is too cold or freezing food in fresh food section.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fresh food thermistor, Stuck air damper open, Main control board temperature logic failure, User settings too cold

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing sensors or dampers.

  • Verify settings: Set fresh food to 37°F (3°C) and freezer to 0°F (-18°C). Avoid max cold settings unless needed.
  • Check damper: Inspect the air damper for a door stuck open, allowing too much cold air into the fresh food section. Replace if broken.
  • Test thermistor: Measure the fresh food thermistor resistance and compare to spec. Replace if out of range.
  • Control board: If damper and thermistor are good but unit still overcools, the main control board may be misreading temperatures and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Air Damper Assembly
Check Price on Amazon