GE Profile
Temperature Control or Thermistor Miscalibration
Refrigerator runs constantly and is too cold or freezing food in fresh food section.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty fresh food thermistor, Stuck air damper open, Main control board temperature logic failure, User settings too cold
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing sensors or dampers.
- Verify settings: Set fresh food to 37°F (3°C) and freezer to 0°F (-18°C). Avoid max cold settings unless needed.
- Check damper: Inspect the air damper for a door stuck open, allowing too much cold air into the fresh food section. Replace if broken.
- Test thermistor: Measure the fresh food thermistor resistance and compare to spec. Replace if out of range.
- Control board: If damper and thermistor are good but unit still overcools, the main control board may be misreading temperatures and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Air Damper Assembly
Check Price on Amazon