E17
Grundig Freezer Temperature Regulation Fault

Display shows E17 and the freezer temperature fluctuates widely or does not reach the set point.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Intermittent freezer NTC sensor, Loose sensor connector on PCB, Sticking compressor or fan relay, Software control anomaly

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before accessing sensors or the main PCB.

  • Verify actual temperature: Place an accurate thermometer in the freezer to confirm the real temperature versus the display.
  • Inspect freezer sensor connection: Access the main PCB and ensure the freezer NTC sensor connector is firmly seated. Wiggle gently to check for intermittent contact.
  • Check wiring harness: Look for signs of damage where the sensor wires pass through the cabinet.
  • Replace suspect sensor: If the sensor readings are unstable or out of range, replace the freezer NTC sensor with a Grundig-compatible part.
  • Reset control: After sensor replacement, unplug the unit for several minutes, then restore power and monitor freezer performance over 24 hours.

If E17 persists and temperatures remain unstable, the main PCB may be faulty and should be replaced by a professional.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer Compartment NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements