dF
Haier Defrost Mode Indication / Defrost Circuit Error

Display shows dF and the refrigerator may be stuck in defrost or show defrost-related issues.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Control stuck in defrost mode, Faulty defrost sensor feedback, Defective main PCB defrost logic, Wiring issue in defrost circuit

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before testing the defrost circuit. The heater operates at mains voltage.

Steps:

  • 1. Wait and observe: Some Haier models briefly display dF during a normal defrost cycle. If it clears within 30–60 minutes and cooling resumes, no fault is present.
  • 2. If dF persists: Unplug the unit for 10–15 minutes and plug back in. If dF reappears and cooling does not resume, proceed with defrost system checks.
  • 3. Check defrost sensor and heater: Test the defrost sensor and heater as described in the E4 and E5 entries. Replace any failed components.
  • 4. Inspect wiring: Verify continuity from the heater and sensor to the main PCB. Repair any damaged harnesses.
  • 5. Replace main PCB: If all defrost components and wiring are good but the control remains stuck in defrost (dF), the main control board is likely faulty and should be replaced.

Note: After repair, allow a full cooling cycle to confirm normal operation.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements