F3
Haier
Defrost Sensor Fault (Alternate Code)
Display shows F3 and the unit may have defrost-related cooling issues.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted defrost sensor, Sensor not attached to evaporator, Wiring damage, Main PCB sensor input failure
How to Fix / Troubleshooting
Safety: Disconnect power before accessing the evaporator area.
Steps:
- 1. Access evaporator: Remove freezer drawers and rear panel.
- 2. Locate defrost sensor: Find the sensor clipped to the evaporator tubing.
- 3. Inspect and test: Check for damage and measure resistance. Replace if faulty.
- 4. Check harness: Verify continuity to the main PCB. Repair as needed.
- 5. Replace PCB: If all else is good but F3 persists, replace the main control board.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Defrost Sensor / Defrost Thermistor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements