Haier Defrost System Failure

Freezer cold but refrigerator section warm; frost buildup on back wall of freezer.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed defrost heater, Open defrost thermostat/thermal fuse, Faulty defrost sensor, Main PCB not initiating defrost

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before accessing the evaporator and heater. The heater is high voltage.

Steps:

  • 1. Defrost manually: Unplug the unit and allow all ice to melt (24–48 hours with doors open). This will temporarily restore airflow.
  • 2. Access evaporator: Remove freezer drawers and rear panel to expose the evaporator, heater, and defrost components.
  • 3. Test heater and thermostat: Use a multimeter to check continuity of the defrost heater and thermostat. Replace any open components.
  • 4. Test defrost sensor: Measure resistance of the defrost sensor and compare to spec. Replace if out of range.
  • 5. Control board: If all components are good but frost returns quickly, the main control board may not be initiating defrost and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost Heater Assembly