dF
Hisense
Defrost Mode or Defrost Feedback Error
Display shows dF and the unit may be stuck in defrost or show abnormal defrost timing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defrost sensor not reporting correctly, Stuck defrost relay on PCB, Software glitch in defrost control, Wiring fault in defrost feedback circuit
How to Fix / Troubleshooting
Safety: Unplug the refrigerator before accessing the control board or evaporator area.
- 1. Power reset: Disconnect power for 10 minutes, then restore. If dF clears and normal operation resumes, monitor.
- 2. Check defrost sensor: Inspect and test the evaporator/defrost thermistor as described in E3/F3 entries.
- 3. Inspect main PCB: Look for signs of overheating near the defrost relay. If the relay appears burnt or stuck, the board likely needs replacement.
- 4. Verify wiring: Ensure the defrost heater and sensor wiring are intact and properly connected.
Board-level faults generally require replacement of the main PCB by a technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board (PCB)
Check Price on Amazon
We may earn a commission from links on this page.