E11
Hotpoint Door Switch / Reed Sensor Fault

Display shows E11 and the door alarm may sound even when doors are closed.

Advertisements

Possible Causes

Failed door switch or reed sensor, Misaligned door magnet, Broken door switch wiring, Faulty input on main control board

How to Fix / Troubleshooting

Safety first: Disconnect power before removing control covers or door switch housings.

Inspection:

  • Locate the door switch or magnetic reed sensor (usually in the cabinet frame or control housing).
  • Check that the door closes fully and that gaskets are not preventing proper contact.
  • Verify that the door magnet (if used) is present and aligned with the sensor.

Testing:

  • Press the mechanical switch by hand; you should hear a distinct click.
  • Test continuity across the switch terminals while pressing and releasing; replace if it does not change state.

Corrective action: Replace any faulty door switch or reed sensor. If the sensor is good but E11 persists, the main control board may be misreading the input and require replacement.