E12
IceKing
Ambient Temperature Sensor Fault
Display shows E12 and the refrigerator may run continuously or not reach the set temperature.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ambient NTC sensor, Sensor dislodged from mounting position, Damaged wiring to ambient sensor, Faulty main PCB sensor input
How to Fix / Troubleshooting
Safety warning: Disconnect mains power before accessing any sensors or control boards.
Steps:
- 1. Identify the ambient sensor: On IceKing refrigerators, the ambient sensor is often located behind the front control panel or near the condenser area to measure room temperature.
- 2. Visual inspection: Check that the sensor is properly mounted and not hanging loose. Inspect the harness for cuts or abrasions.
- 3. Resistance test: Disconnect the sensor and measure its resistance at room temperature. Compare to the expected NTC curve in the service documentation. Replace if open, shorted, or far out of range.
- 4. Harness continuity: If the sensor is good, test continuity from the sensor connector to the main PCB. Repair any damaged wiring.
- 5. PCB evaluation: If sensor and wiring are OK but E12 persists, the main PCB may misread the ambient sensor and should be replaced by a technician.
Note: An incorrect ambient reading can cause the refrigerator to overcool or undercool depending on the error direction.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient NTC Temperature Sensor
Check Price on Amazon