E16
IceKing Freezer Overcool / Control Calibration Fault

Display shows E16 and the freezer temperature drops excessively low or fluctuates.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Misreading freezer NTC sensor, Stuck relay on main PCB, Incorrect control calibration, Shorted wiring causing false low temperature reading

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before testing sensors or PCB connections.

Steps:

  • 1. Verify actual temperature: Place an accurate thermometer in the freezer and compare to the displayed temperature. Note any large discrepancy.
  • 2. Check freezer NTC sensor: Access the freezer sensor as described for E2. Measure its resistance at a known temperature and compare to the expected curve. Replace if out of range.
  • 3. Inspect wiring: Look for shorted or pinched wires between the sensor and PCB that could cause a false low reading.
  • 4. Control reset: After sensor replacement, unplug the unit for 5–10 minutes to reset the control. Reprogram temperature settings and monitor.
  • 5. PCB replacement: If the sensor and wiring are correct but the control continues to overcool and shows E16, the main PCB may be miscalibrated or have a stuck output and should be replaced.

Note: Prolonged overcooling can cause excessive frost and food damage; address promptly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer Compartment NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements