F17
Ikea
High Temperature Protection or Overheat Fault
Error F17 appears and the refrigerator may not start the compressor, remaining warm.
Advertisements
Possible Causes
Overheated compressor due to poor ventilation, Blocked condenser coils, Failed thermal protector on compressor, Faulty temperature monitoring on control board
How to Fix / Troubleshooting
Safety: Unplug the refrigerator before cleaning coils or touching the compressor. The compressor can be very hot.
Steps:
- 1. Check ventilation: Ensure there is adequate space around the refrigerator (top, sides, and back) as specified in the Ikea installation instructions. Built-in models must have proper airflow channels.
- 2. Clean condenser coils: Remove the rear lower cover and vacuum dust from the condenser coils and fan area. Clogged coils cause overheating.
- 3. Allow cooling: If the compressor is extremely hot, leave the unit unplugged for 1–2 hours to allow it to cool and reset any thermal protectors.
- 4. Inspect condenser fan: Verify that the condenser fan runs when the compressor is on (see condenser fan fault if not).
- 5. Control board: If ventilation and cooling are normal but F17 persists, the control board’s temperature monitoring circuit may be faulty and require replacement.
Tip: Regularly cleaning condenser coils (every 6–12 months) helps prevent overheating faults.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Condenser Coil / Condenser Fan Motor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements