F19
Ikea Compressor Control Circuit Fault

Error F19 appears and the refrigerator may not cool, with the compressor not receiving a start signal.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor relay on main board, Broken wiring between board and compressor, Faulty inverter control signal, Internal board logic failure

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before accessing the control board or compressor wiring. Live mains voltage is present in this area.

Steps:

  • 1. Inspect wiring: Check the harness from the main control board to the compressor or inverter module for damage or loose connectors.
  • 2. Listen for relay: Briefly plug in and listen for a click from the compressor relay when cooling should start. Then unplug again. No click may indicate a failed relay or control logic.
  • 3. Board inspection: Remove the control board and inspect for burnt relay contacts or damaged traces.
  • 4. Replace board: If the relay is faulty or the board is damaged, replace the main control board with the correct Ikea-compatible part.
  • 5. Verify compressor: If a new board does not resolve the issue, the compressor or inverter may be faulty and should be tested by a professional.

Warning: Do not attempt to bypass safety circuits or hard-wire the compressor; this is dangerous and can cause fire or further damage.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements