Indesit
User Interface Keypad Failure
Display panel lights up but buttons do not respond or settings cannot be changed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty touch panel or keypad, Moisture behind display, Loose ribbon cable, Control board not reading key inputs
How to Fix / Troubleshooting
Safety first: Unplug before removing the display panel.
Step-by-step checks:
- 1. Power reset: Disconnect power for 10 minutes to reset the electronics.
- 2. Inspect panel: Remove the display fascia and check for moisture or corrosion. Dry carefully if damp.
- 3. Reseat ribbon cable: Disconnect and reconnect the keypad ribbon cable to ensure a good connection.
When to call a technician: If keys remain unresponsive, the UI panel or main PCB may need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
User Interface / Touch Control Panel