A3
Indesit
Door Open / Door Switch Alarm
A3 alarm or code, rapid temperature fluctuations, appliance may run loudly or continuously.
Advertisements
Possible Causes
Faulty door switch, Misaligned door causing switch not to actuate, Broken door hinge, Damaged door gasket causing frequent warm air ingress
How to Fix / Troubleshooting
Safety first: Disconnect power before removing switch components.
Step-by-step checks:
- 1. Confirm door closure: Ensure nothing is obstructing the door. Check shelves and tall containers.
- 2. Test door switch: Locate the door switch (usually in the frame). Press it in and listen for interior light turning off or a click. If no change, the switch may be faulty.
- 3. Inspect hinge and alignment: Check that the door is level and aligned with the cabinet. Adjust hinge screws if the door is sagging.
- 4. Replace switch if needed: Remove the switch, disconnect the wires, and install a new Indesit-compatible door switch.
When to call a technician: If the switch is good but the alarm persists, the control board input may be faulty.
Advertisements
Repair Difficulty
Easy
2/5