F07
Indesit Ambient Temperature Sensor Fault

F07 error on display, refrigerator may not cool or may run continuously, temperature readings appear incorrect.

Advertisements

Possible Causes

Defective ambient NTC sensor, Sensor dislodged from housing, Wiring damage between sensor and PCB, Control board sensor input failure

How to Fix / Troubleshooting

Safety first: Unplug the appliance before accessing external sensor housings or control boards.

Step-by-step checks:

  • 1. Locate ambient sensor: On many Indesit models, the ambient sensor is located behind a small grille on the front frame or at the rear near the condenser area.
  • 2. Visual inspection: Remove the grille or cover and inspect the sensor capsule and wiring for damage or signs of water ingress.
  • 3. Resistance test: Disconnect the sensor and measure resistance. Compare to expected NTC values for room temperature. Replace if open, shorted, or far out of range.
  • 4. Refit correctly: Ensure the new sensor is placed in the correct location, not touching hot components, and not buried in insulation.

When to call a technician: If the sensor and wiring are good but F07 remains, the main PCB may require replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.