E7
JennAir Ambient Temperature Sensor Fault

Display shows E7; ambient temperature readings may be incorrect, affecting cooling performance.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted ambient thermistor, Sensor dislodged from proper location, Damaged harness to control board, Faulty main control board sensor circuit

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing any sensors behind panels or grilles.

  • Locate ambient sensor: On many JennAir models, the ambient thermistor is located behind the toe grille or in the machine compartment, sensing room temperature.
  • Inspect sensor and wiring: Check for broken wires, corrosion, or a sensor that has come loose from its mounting point.
  • Test sensor: Remove the thermistor and measure resistance at room temperature. Compare to the expected NTC value (~2.7–3.5 kΩ at 77°F). Replace if open, shorted, or far out of range.
  • Reinstall correctly: Mount the new sensor in the same location, away from hot components like the compressor or condenser.
  • Control board: If E7 remains after sensor replacement and wiring checks, the main control board may be faulty and should be evaluated by a technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Thermistor
Check Price on Amazon