PE
JennAir
Power Error / Control Board Reset Required
Display shows PE and may beep; refrigerator may not respond to temperature changes or may not cool correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Voltage fluctuation, Control board software glitch, Loose wire harness at main control board, Faulty electronic control board
How to Fix / Troubleshooting
Safety first: Always disconnect power at the wall outlet or breaker before removing any panels.
- Soft reset: Unplug the refrigerator or switch off the circuit breaker for 5 minutes. Restore power and see if the PE code clears.
- Check outlet voltage: If you have a multimeter and are qualified to use it, verify that the outlet provides a stable 110–120 VAC. Do not attempt this if you are not comfortable working with live voltage.
- Inspect power cord and plug: Look for burn marks, cuts, or loose fit in the outlet. A damaged cord or loose outlet can cause intermittent power errors.
- Control board connections: With power disconnected, remove the rear access cover and visually inspect the main control board harness connectors. Reseat any loose connectors firmly.
- When to call a technician: If the PE code returns immediately after a reset and connections are secure, the electronic control board is likely faulty and should be tested and replaced by a professional.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements