Possible Causes

Weak door magnet or misaligned reed switch, Failing door switch, Warped door gasket, Sagging door hinges

How to Fix / Troubleshooting

Safety first: Keep the unit plugged in to observe alarm behavior, but avoid leaving doors open for long periods.

Steps:

  • 1. Gently press door: When the alarm sounds, press on each door. If the alarm stops, that door is not sealing or closing fully.
  • 2. Inspect gasket and hinges: Look for warped gaskets or sagging doors. Adjust hinges and reshape or replace gaskets as needed.
  • 3. Test door switches: Manually press each door switch and see if the alarm stops. Replace any switch that does not reliably signal door closed.
  • 4. Check for obstructions: Ensure shelves or food items are not preventing full closure.