Er CO
LG
Communication Error Between Main PCB and Display PCB
Error code “Er CO” appears and some functions may be disabled; display may be unresponsive.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose or damaged communication harness, Corroded connectors at display or main board, Failed display PCB, Failed main control board
How to Fix / Troubleshooting
Safety: Disconnect power before removing control panels.
- Power reset: Unplug the unit for 5–10 minutes, then plug back in. If Er CO returns, proceed.
- Access display PCB: Remove the control panel cover (on the door or inside the refrigerator ceiling, depending on model). Carefully disconnect the ribbon cable or harness.
- Inspect connectors: Look for bent pins, corrosion, or loose plugs. Clean lightly with electronic contact cleaner if needed and reseat firmly.
- Check harness continuity: Using a multimeter, verify continuity of each wire between the display PCB and main PCB connectors. Replace the harness if any wire is open.
- Board replacement: If wiring is good, replace the display PCB first (most common). If the error persists, the main PCB may also need replacement.
Note: Handle PCBs by the edges and avoid static discharge by grounding yourself.