F10
Liebherr Ice Maker Sensor / Position Fault

Error code F10; ice maker may stop working or produce irregular ice, and water feed may be interrupted.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ice maker position sensor, Jammed ice tray or ejector arm, Broken ice maker harness in door, Faulty ice maker module electronics

How to Fix / Troubleshooting

Safety first: Turn off the ice maker and unplug the refrigerator before working in the ice compartment.

Step-by-step:

  • Inspect ice maker: Remove the ice bin and visually inspect the ice maker for jammed cubes, broken plastic parts, or frost buildup.
  • Clear jams: Gently remove any stuck ice cubes. Do not use sharp tools that could damage the mold or sensors.
  • Check movement: Manually move the ejector arm or tray (if possible) to ensure it is not seized.
  • Wiring inspection: Check the harness from the cabinet to the ice maker, especially in the door hinge area, for broken or pinched wires.
  • Reset ice maker: Some Liebherr models have a reset button or require turning the ice maker off for several minutes, then back on. Follow the user manual procedure.
  • Replace module if needed: If the sensor or motor is defective, replace the complete Liebherr ice maker assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ice Maker Assembly
Check Price on Amazon