Error code F8; compressor may not start or may run continuously; cooling performance is abnormal.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Unplug the refrigerator. Work on compressor and inverter only if you are experienced; high voltages are present.
Step-by-step:
- Listen for compressor: After restoring power briefly, listen at the back of the unit. If the compressor does not start or clicks repeatedly, there may be an inverter or compressor issue.
- Inspect inverter module: Remove the rear lower cover to access the compressor and attached inverter module. Look for burn marks, melted plastic, or a burnt smell.
- Check wiring: Verify that the multi-pin connector between the main control board and inverter is fully seated and undamaged.
- Power reset: Disconnect power for 10 minutes, then reconnect and observe if F8 returns immediately or after a short run.
- Do not bypass safety circuits: Do not attempt to hard-wire the compressor; this is dangerous and can cause further damage.
When to call a technician: F8 typically requires professional diagnosis with proper tools to test the inverter and compressor windings. A certified Liebherr technician should handle replacement of the inverter module or compressor.
Repair Difficulty
Required Part
We may earn a commission from links on this page.