Possible Causes
Refrigerant leak in evaporator or tubing, Partial blockage in capillary tube, Weak compressor, Frost pattern limited to small section of evaporator
How to Fix / Troubleshooting
Safety First: Do not attempt to open the sealed refrigeration system unless you are a certified technician.
Steps (User-Level Checks):
- Check door seal and loading: Ensure the freezer door gasket seals well and the compartment is not overpacked, blocking airflow.
- Inspect frost pattern: With power off and the rear freezer panel removed, observe the evaporator after 10–15 minutes of running (technician-level). A normal pattern is even frost across most of the coil; a small frosted patch suggests a sealed system issue.
- Clean condenser: Make sure condenser coils and fan are clean and operating properly to avoid false symptoms.
- Professional service: If airflow and defrost are normal but freezing is weak, contact a qualified refrigeration technician for leak detection and sealed system repair.