Display shows F10; refrigerator may not cool, or compressor may not run at all.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Unplug the appliance before cleaning coils or accessing the rear compartment. Do not damage refrigerant lines.
Steps:
- Check ventilation: Ensure there is sufficient space around the refrigerator per Miele installation instructions. Poor airflow can cause overheating.
- Clean condenser: Remove the lower rear cover and gently vacuum or brush dust from the condenser coils. Use a soft brush to avoid bending fins.
- Verify condenser fan operation: With power restored, observe whether the condenser fan runs when the compressor is on. If not, unplug and test the fan for free rotation and continuity. Replace if defective.
- Allow cool‑down: If the compressor is very hot to the touch, leave the unit unplugged for 30–60 minutes, then restart.
If F10 recurs after cleaning and verifying fan operation, a sensor or sealed system issue may be present. Contact a Miele service technician.