Neff Door Open Detection / Alarm Circuit Fault

Display shows E22 and the refrigerator interior light or fan may stay off even with door closed.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty door sensor, Misaligned door, Damaged door harness, Faulty alarm circuit on main PCB

How to Fix / Troubleshooting

Safety: Disconnect power before adjusting doors or accessing wiring.

Steps:

  • Check door alignment: Ensure the door closes fully and seals evenly. Adjust hinges if the door is sagging.
  • Inspect gasket: Look for gaps or twists in the door gasket that might prevent proper closure.
  • Door sensor test: As with E10, locate the door reed switch or sensor and test its operation with a magnet and multimeter. Replace if faulty.
  • Harness inspection: On models with wiring through the door hinge, inspect for broken or pinched wires.
  • PCB check: If the sensor and door alignment are correct but E22 persists, the alarm circuit on the main PCB may be defective and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Door Sensor / Main Control Board