H27
Panasonic Ambient (Room) Temperature Sensor Error

Display shows H27, refrigerator may run continuously or not reach set temperature

Advertisements

Possible Causes

Defective ambient thermistor, Sensor dislodged from correct location, Broken sensor wiring, Main PCB sensor input failure

How to Fix / Troubleshooting

Safety: Disconnect power before removing any external covers.

  • Step 1 – Locate ambient sensor: On many Panasonic models, the ambient sensor is located behind a small grille on the cabinet front or rear, or near the control panel.
  • Step 2 – Inspect sensor: Ensure the sensor is not covered by tape, dust, or insulation. It must be exposed to room air.
  • Step 3 – Wiring check: Inspect the harness from the sensor to the main PCB for damage. Reseat connectors at both ends.
  • Step 4 – Replace sensor: If the sensor is physically damaged or tests open/short with a multimeter, replace it with the correct Panasonic ambient thermistor.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature Sensor
Check Price on Amazon