E9
Siemens
Defrost Sensor or Heater Overheat / Short Fault
E9 error displayed; ice build-up on evaporator; fan noise may increase or airflow is weak.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted defrost heater, Shorted evaporator sensor wiring, Defective defrost thermostat stuck closed, Main PCB detecting overcurrent in defrost circuit
How to Fix / Troubleshooting
Safety first: Disconnect mains power before accessing the freezer evaporator or heater wiring.
Procedure:
- 1. Visual inspection: Remove freezer drawers and rear panel. Look for burnt insulation or melted plastic near the heater or wiring.
- 2. Test heater resistance: Disconnect heater leads and measure resistance. A very low resistance (near 0 Ω) or visible damage indicates a shorted heater that must be replaced.
- 3. Inspect wiring harness: Follow the heater and sensor wires. Look for spots where wires may have rubbed against metal and shorted. Repair with proper high-temperature wire and connectors.
- 4. Check defrost thermostat: If fitted, test the thermostat for proper operation (closed when cold, open when warm). A thermostat stuck closed can contribute to overheating.
- 5. Reset and test: After repairs, reassemble, restore power, and monitor for recurrence of E9. If the error returns with all components verified, the main PCB may be misreading current and require replacement.
Note: Use only Siemens-approved heater assemblies and high-temperature wiring in the evaporator area.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Defrost Heater Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements