Siemens Compressor Control Failure

Interior light works but compressor and fans do not run; display may show normal temperatures.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty main PCB compressor relay, Open compressor start device, Defective temperature sensor preventing call for cooling, Stuck in demo/showroom mode

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before accessing rear components.

Steps:

  • 1. Check for demo mode: Some Siemens models have a showroom/demo mode where cooling is disabled. Refer to the user manual to exit demo mode (often a specific button combination).
  • 2. Listen for relay click: When the unit calls for cooling, you should hear a click from the control board area. No click may indicate a failed relay or control logic.
  • 3. Inspect compressor start device: Remove the start relay/overload from the compressor and test as described in compressor start fault procedures. Replace if defective.
  • 4. Evaluate sensors: A sensor reading incorrectly warm or cold can prevent compressor operation. Test NTC sensors and replace if out of spec.
  • 5. Replace main PCB: If start components and sensors are good but the compressor never receives power, the main control board likely needs replacement.

Note: Allow several minutes after power-up for the control to initiate compressor operation; many models have a built-in delay.