EC40
Sub-Zero Evaporator Fan or Air Circulation Fault

Refrigerator displays EC40; unit may run continuously or not maintain set temperatures.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed evaporator fan motor, Ice buildup around fan shroud, Faulty fan speed control on main board, Wiring harness issue to fan

How to Fix / Troubleshooting

Safety first: Disconnect power before removing any interior panels. Fan blades can start unexpectedly if power is applied.

Step 1 – Listen for evaporator fan operation

  • With doors closed for several minutes and the compressor running, you should hear a gentle fan noise from inside the compartment.
  • If the compressor is running but there is no airflow sound, the evaporator fan motor may not be operating.

Step 2 – Inspect for ice obstruction

  • Open the compartment and remove shelves to access the rear evaporator cover.
  • If the cover is bowed, frosted over, or has ice around the fan area, you may have a defrost or door gasket issue causing ice to block the fan.
  • Unplug the unit and allow ice to melt, or carefully use a hair dryer on low to speed thawing (do not overheat plastic).

Step 3 – Access and test the evaporator fan

  • Remove the evaporator cover to expose the fan motor.
  • Check that the fan blade spins freely by hand and is not rubbing on housing.
  • With power off, disconnect the fan and measure resistance across the motor leads. An open circuit indicates a failed motor.

Step 4 – Replace the evaporator fan motor if needed

  • Remove mounting screws and transfer the fan blade to the new motor if not pre‑assembled.
  • Install the new motor, reconnect wiring, and reassemble the evaporator cover and shelves.

Step 5 – Verify operation

  • Restore power and confirm that the fan runs when the compressor is on.
  • Monitor temperatures for 24 hours. If EC40 returns, the main control board or fan speed control circuit may be faulty.

When to call a professional: If the fan tests good but does not receive power, or if multiple fans are affected, contact a Sub‑Zero technician to diagnose the control board and wiring.