F13
V-ZUG Communication Fault Between Main Control Board and User Interface

Display shows F13 or communication error, some functions unavailable, lights may still work

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged data cable between main PCB and display PCB,Corroded connectors at control modules,Faulty user interface board,Defective main control board communication circuit

How to Fix / Troubleshooting

Safety first: Unplug the refrigerator before removing any panels.

Steps:

  • 1. Power reset: Disconnect power for 10–15 minutes, then reconnect. If F13 returns, proceed with inspection.
  • 2. Access user interface: Remove the trim and screws around the display/control panel. Carefully pull it forward.
  • 3. Inspect ribbon/data cable: Check the cable for kinks, cuts, or signs of moisture. Ensure both ends are fully seated in their connectors.
  • 4. Clean connectors: If corrosion is visible, use electrical contact cleaner and allow to dry fully before reconnecting.
  • 5. Check main control board connections: At the rear, open the PCB housing and verify that the communication harness is properly connected.
  • 6. Replace faulty board: If cables are intact but F13 persists, either the user interface PCB or main PCB is defective. Replace the more accessible user interface first, using the correct V-ZUG part.
  • 7. If problem remains: Replace or have a technician test the main control board.

Warning: Handle ribbon cables gently; they are easily damaged.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

User Interface Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements