Vestfrost
Temperature Calibration / Sensor Drift
Digital display shows incorrect temperatures compared to a thermometer inside the compartments.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Aging NTC sensors, Poor sensor placement or contact, Firmware calibration offset, Airflow issues causing stratification
How to Fix / Troubleshooting
Safety: Unplug the refrigerator before accessing sensors or control boards.
Steps to correct temperature readings:
- Verify with a reliable thermometer: Place a thermometer in water in the fridge and in the freezer to get accurate readings.
- Check sensor placement: Ensure sensors are properly clipped and not touching warm lights or cold evaporator surfaces unless designed to.
- Replace drifting sensors: If readings are consistently off and sensors test out of spec, replace the affected NTC sensors.
- Control calibration: Some Vestfrost models allow minor temperature offset adjustments via the menu; consult the user manual.
Note: Allow at least 24 hours after any change for temperatures to stabilize before rechecking.
Advertisements
Repair Difficulty
Medium