E12
Vestfrost Door Switch / Door Sensor Fault

Error E12 displayed; door alarm may sound even when doors are closed properly.

Advertisements

Possible Causes

Defective magnetic door reed switch, Misaligned door magnet, Broken door switch wiring, Faulty input on main PCB

How to Fix / Troubleshooting

Safety: Disconnect power before removing control panels or door trims.

Steps to address E12 (door sensor):

  • Check door closure: Ensure the door is closing fully and not obstructed by shelves, food items, or warped gaskets.
  • Inspect door magnet and switch: On many Vestfrost models, a magnet in the door interacts with a reed switch in the cabinet frame. Verify the magnet is present and not loose. Locate the switch behind the liner or in the top frame.
  • Test the switch: With the refrigerator unplugged, access the switch and test continuity with a multimeter while placing a magnet near it. The switch should open/close as the magnet is moved.
  • Check wiring: Inspect the harness from the switch to the control board for damage, especially near hinge areas.
  • Replace faulty components: Install a new door switch or magnet as needed. If the PCB input is faulty, the main board may require replacement.

Tip: After repair, verify that the interior light turns off when the door is closed and that the alarm no longer sounds.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch (Reed Switch) and Door Magnet
Check Price on Amazon

We may earn a commission from links on this page.