E6
Vestfrost Main Control Board Communication / Internal Fault

Error E6 on display; interior lights and fans may work but cooling is poor or absent.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Internal failure of main PCB, Corrupted EEPROM or firmware, Shorted low-voltage circuit, Power surge damage

How to Fix / Troubleshooting

Safety: Disconnect the refrigerator from mains before opening any control panel.

Steps to handle E6 (control board fault):

  • Power reset: Unplug the unit for 10–15 minutes, then reconnect. If E6 reappears immediately, continue.
  • Check for external causes: Verify that the outlet is properly grounded and not shared with heavy inductive loads (e.g., large motors) that can cause surges. Try a different outlet if possible.
  • Inspect the main PCB: Access the control board (usually behind a rear metal cover or in the top control housing). Look for burnt components, bulging capacitors, or signs of moisture ingress.
  • Check connectors: Reseat all harness connectors to the PCB, ensuring firm contact and correct orientation.
  • Replace the main control board: If visible damage is present or E6 persists after reseating connectors, replace the board with the exact Vestfrost part number. Transfer any jumper settings or wiring positions exactly as on the original.

Note: Some models may require a specific initialization or parameter setting after PCB replacement; refer to Vestfrost service documentation or use an authorized technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control Board (PCB)