Vestfrost Defrost System Failure

Excessive frost or ice buildup on the back wall of the freezer compartment.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed defrost heater, Defective defrost sensor or thermal fuse, Faulty defrost control on PCB, Door gasket leaks allowing moist air in

How to Fix / Troubleshooting

Safety: Unplug the refrigerator before defrosting or testing components.

Steps to resolve heavy frost:

  • Manual defrost: Remove food, unplug the unit, and allow all ice to melt. Use towels to collect water; do not use sharp tools.
  • Test defrost components: Access the evaporator and check the defrost heater and sensor as described in the E3/E4/E9 procedures. Replace any faulty parts with Vestfrost-compatible components.
  • Inspect door gaskets: Replace damaged or deformed freezer door seals to reduce moisture ingress.
  • Control board check: If heater and sensor are good, the main PCB may not be initiating defrost and may need replacement.

After repair: Reassemble and allow 24 hours for normal frost pattern to return.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost Heater
Check Price on Amazon

We may earn a commission from links on this page.