E13
Viking Ambient / Room Temperature Sensor Failure

Display shows E13; refrigerator may show incorrect temperature readings or fluctuate unexpectedly.

Advertisements

Possible Causes

Failed ambient thermistor, Damaged sensor wiring near top grille, Loose connector at control board

How to Fix / Troubleshooting

Safety first: Disconnect power before accessing the top grille or control compartment.

Steps:

  • Locate ambient sensor: Often mounted near the top grille or air intake area, sometimes behind a small vented cover.
  • Inspect sensor: Check for physical damage, paint, or debris covering the sensor.
  • Test resistance: Disconnect the sensor and measure resistance with a multimeter. Compare to the expected value for room temperature (commonly ~10kΩ at 77°F / 25°C). Replace if open, shorted, or out of spec.
  • Check harness: Ensure the wiring from the sensor to the main control is intact and connectors are fully seated.

Corrective action: Replace the ambient thermistor if defective. After replacement, restore power and allow several hours for temperature control to stabilize.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ambient Temperature Sensor / Thermistor
Check Price on Amazon

We may earn a commission from links on this page.