E13
Viking
Ambient / Room Temperature Sensor Failure
Display shows E13; refrigerator may show incorrect temperature readings or fluctuate unexpectedly.
Advertisements
Possible Causes
Failed ambient thermistor, Damaged sensor wiring near top grille, Loose connector at control board
How to Fix / Troubleshooting
Safety first: Disconnect power before accessing the top grille or control compartment.
Steps:
- Locate ambient sensor: Often mounted near the top grille or air intake area, sometimes behind a small vented cover.
- Inspect sensor: Check for physical damage, paint, or debris covering the sensor.
- Test resistance: Disconnect the sensor and measure resistance with a multimeter. Compare to the expected value for room temperature (commonly ~10kΩ at 77°F / 25°C). Replace if open, shorted, or out of spec.
- Check harness: Ensure the wiring from the sensor to the main control is intact and connectors are fully seated.
Corrective action: Replace the ambient thermistor if defective. After replacement, restore power and allow several hours for temperature control to stabilize.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor / Thermistor
Check Price on Amazon
We may earn a commission from links on this page.