E15
Viking Ice Level Sensor / Optics Error

Display shows E15; ice level may not be detected correctly, causing overfilling or no ice production.

Advertisements

Possible Causes

Failed ice level optics board, Dirty or blocked ice level sensor window, Misaligned ice bin or sensor bracket

How to Fix / Troubleshooting

Safety first: Disconnect power before working around the ice bin and sensor boards.

Steps:

  • Locate ice level sensor: Many Viking models use infrared optics on the side walls of the ice compartment.
  • Clean sensor windows: Use a soft cloth and mild soap solution to clean the emitter and receiver windows. Dry thoroughly.
  • Check bin position: Ensure the ice bin is fully seated and not blocking the sensor beam.
  • Visual inspection: Inspect the optics boards for corrosion, cracked housings, or loose connectors.

Corrective action: If cleaning and reseating do not restore normal operation, replace the ice level optics kit (emitter and receiver boards) as a set to ensure proper calibration.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ice Level Optics Sensor Kit
Check Price on Amazon