E15
Viking
Ice Level Sensor / Optics Error
Display shows E15; ice level may not be detected correctly, causing overfilling or no ice production.
Advertisements
Possible Causes
Failed ice level optics board, Dirty or blocked ice level sensor window, Misaligned ice bin or sensor bracket
How to Fix / Troubleshooting
Safety first: Disconnect power before working around the ice bin and sensor boards.
Steps:
- Locate ice level sensor: Many Viking models use infrared optics on the side walls of the ice compartment.
- Clean sensor windows: Use a soft cloth and mild soap solution to clean the emitter and receiver windows. Dry thoroughly.
- Check bin position: Ensure the ice bin is fully seated and not blocking the sensor beam.
- Visual inspection: Inspect the optics boards for corrosion, cracked housings, or loose connectors.
Corrective action: If cleaning and reseating do not restore normal operation, replace the ice level optics kit (emitter and receiver boards) as a set to ensure proper calibration.