E007
Bosch
Boundary Wire Signal Not Detected
Display shows E007 and mower refuses to start mowing cycle
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken perimeter wire, Disconnected boundary wire at charging station, Faulty boundary wire connector, Defective charging station transmitter
How to Fix / Troubleshooting
Safety: Unplug the charging station from mains before handling boundary wires.
- Check LED on charging station: On Bosch Indego stations, a steady or flashing LED indicates boundary status. Refer to the manual for LED meaning; if off, check power supply.
- Inspect boundary wire connections: Ensure both ends of the loop are firmly inserted into the station terminals and that the insulation is stripped correctly.
- Walk the perimeter: Look for visible cuts, damage from gardening tools, or rodent bites. Pay special attention to path crossings and edges.
- Use a wire break locator or multimeter: Measure continuity of the loop from the station. A high resistance or open circuit indicates a break that must be repaired with Bosch-compatible boundary wire connectors.
- If the loop is intact: The charging station PCB or its transmitter coil may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Boundary Wire and Connectors
Check Price on Amazon
We may earn a commission from links on this page.