E011
Bosch
Battery Temperature Out of Range
Mower shows E011 and refuses to start; often after long storage
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Battery too cold, Battery overheated, Faulty battery temperature sensor (NTC), Battery stored incorrectly
How to Fix / Troubleshooting
Safety: Do not attempt to charge a visibly damaged or swollen battery.
- Check ambient temperature: Bosch robot mowers typically operate and charge best between about 5°C and 45°C. Move the mower and station to a moderate temperature location.
- Allow acclimatization: If the mower was stored in a cold shed or hot sun, let it sit unplugged for 1–2 hours at room temperature.
- Try charging again: Place the mower on the dock and see if E011 clears after some time.
- If error persists at normal temperature: The battery temperature sensor inside the pack or its wiring to the main board may be faulty. Replacement of the battery pack or inspection of the sensor wiring is required.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Battery Pack with Temperature Sensor
Check Price on Amazon