Ecovacs No Power / Dead Mower

Robot lawnmower does not start at all; no lights or display when power switch is turned on.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Main power switch failed, Battery pack completely discharged or defective, Internal fuse blown on mainboard, Loose battery connector

How to Fix / Troubleshooting

Safety first: Do not short battery terminals. Turn the power switch OFF before opening the housing.

  • Check power switch: Confirm the main power switch is firmly in the ON position. Toggle it several times to clear oxidation.
  • Charge on station: Place the mower on the charging station and leave it for at least 2–3 hours. Look for any charging indicators.
  • Inspect battery connection: Remove the cover and verify that the battery connector is fully seated on the mainboard.
  • Check internal fuse (if accessible): Some Ecovacs models include a replaceable fuse on the mainboard or near the battery. Replace only with the same rating.

If the mower remains completely unresponsive after these checks, the battery pack or main control board is likely defective and should be replaced.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Battery Pack
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements