Einhell
Reduced Battery Capacity / Early Low‑Voltage Cutoff
Robot lawnmower starts but stops after a few minutes without any error code; then returns to the station.
Advertisements
Possible Causes
Aged lithium‑ion cells, Battery not fully charging due to dirty contacts, High resistance in battery connector, Battery management circuit degradation
How to Fix / Troubleshooting
Safety first: Turn OFF the mower and unplug the charging station before cleaning contacts or opening covers.
- Clean charging contacts: Use a dry cloth and fine abrasive pad to clean oxidation from the mower and station contacts. Ensure good metal‑to‑metal contact.
- Check charge time: Allow the mower to remain in the station for the full recommended charge time. Confirm that the charging indicator shows a full charge before starting.
- Inspect battery connector: Open the battery compartment and ensure the connector is tight. Look for signs of heat or discoloration, which indicate high resistance.
- Evaluate runtime: Compare current runtime to the original specification. If it is significantly shorter, replace the battery pack with an original Einhell unit.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements