Flymo
Power Interruption / Electronics Instability
Robot mower occasionally reboots or restarts by itself during mowing.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose battery connector, Failing battery pack, Intermittent main switch, Faulty main PCB
How to Fix / Troubleshooting
Safety first: Turn OFF the mower and remove it from the lawn.
- Check main switch: Ensure the main power switch moves positively between OFF and ON and is not loose.
- Inspect battery connection: If accessible, verify that the battery connector is firmly seated and not corroded.
- Monitor runtime: If reboots occur when the blades start or under heavy load, the battery may be weak and dropping voltage.
- Replace suspect parts: Start with a new battery pack; if the issue persists, the main PCB or switch assembly may need replacement.
Advertisements
Repair Difficulty
Hard
4/5