Error 1
Gardena Boundary Loop Signal Out of Range

Display shows “Error 1 – Outside working area” and mower stops near or beyond the boundary wire.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken boundary wire, Loose or corroded boundary wire connector, Defective boundary loop output on Gardena charging station, Boundary wire laid incorrectly around obstacles

How to Fix / Troubleshooting

Safety first: Press the STOP button, switch the main power OFF on the mower, and unplug the charging station power supply before touching any wiring.

  • Check mower position: Move the mower manually back inside the lawn area and restart it on the charging station. If the error clears, the mower may have been outside the loop.
  • Inspect boundary wire path: Walk the entire loop. Look for visible cuts, nail/screw damage, or places where garden work may have broken the wire.
  • Test for wire break: Disconnect the boundary wire ends from the Gardena charging station. Use a simple continuity tester or multimeter to confirm the loop is closed. Infinite resistance indicates a break.
  • Repair damaged wire: Cut out damaged sections and reconnect using original Gardena boundary wire connectors. Ensure the copper conductors are fully inserted and the gel-filled connector is firmly crimped.
  • Check connectors at charging station: Make sure the boundary wire is fully inserted into the left and right boundary terminals and that the screws/clamps are tight and corrosion-free.
  • Verify loop layout: Confirm the wire is not routed too far from the lawn edge or around metal objects that can distort the signal. Adjust according to the Gardena installation guide.
  • Power cycle: Reconnect the boundary wire, plug in the power supply, wait 1–2 minutes, then restart the mower on the station.

If Error 1 persists with a known-good loop, the charging station’s loop generator may be faulty and should be tested or replaced by a technician.