Possible Causes
Loose battery connector, Failing battery cells, Faulty main power switch contacts, Cracked solder joints on power input of main PCB
How to Fix / Troubleshooting
Safety first: Turn OFF the mower and remove the battery if possible.
- Check battery fit: Ensure the battery is fully latched and cannot move when the mower is bumped.
- Inspect connectors: Look for discoloration, melting, or looseness at the battery plug and main switch.
- Test on charger: Place the mower on the station and see if it runs longer while docked (if model allows). Sudden shutdowns point to battery or power path issues.
If intermittent shutdowns continue, the battery or main PCB power section likely needs replacement.