Greenworks Intermittent Power Loss

Robot mower starts but stops after a few seconds without showing an error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose battery connector, Failing battery cells, Faulty main power switch contacts, Cracked solder joints on power input of main PCB

How to Fix / Troubleshooting

Safety first: Turn OFF the mower and remove the battery if possible.

  • Check battery fit: Ensure the battery is fully latched and cannot move when the mower is bumped.
  • Inspect connectors: Look for discoloration, melting, or looseness at the battery plug and main switch.
  • Test on charger: Place the mower on the station and see if it runs longer while docked (if model allows). Sudden shutdowns point to battery or power path issues.

If intermittent shutdowns continue, the battery or main PCB power section likely needs replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Power Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements