Guide 1 not found
Husqvarna
Guide wire 1 signal missing
Display shows “Guide 1 not found” and mower has difficulty returning to the charging station via guide 1.
Advertisements
Possible Causes
Broken guide 1 wire, Loose guide 1 terminal connection, Incorrect guide wire installation, Faulty station guide output
How to Fix / Troubleshooting
Safety first: Disconnect the station power before handling wires.
- Check terminal: Verify the guide 1 wire is firmly connected to the correct terminal on the charging station.
- Inspect wire route: Walk along the guide 1 path and look for damage from gardening tools, rodents, or ground movement.
- Repair breaks: Use Husqvarna waterproof connectors to splice any damaged sections.
- Test LED: After repair, restore power and confirm the station LED indicates a healthy loop.
- Recalibrate guide: Use the mower’s guide calibration function if available.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements