Guide 3 not found
Husqvarna Guide wire 3 signal missing

Display shows “Guide 3 not found” on models with a third guide and mower fails to use that path.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Broken guide 3 wire, Loose terminal, Incorrect installation, Station guide 3 output fault

How to Fix / Troubleshooting

Safety first: Disconnect power to the station.

  • Check terminal and splices: Ensure guide 3 is correctly connected at the station and spliced into the boundary at the far end.
  • Inspect route: Walk the guide 3 path and repair any damage using Husqvarna connectors.
  • Test with short loop: Connect a short test wire as guide 3 to verify station output.
  • Service station: If no guide 3 signal is present even with a test wire, the charging station may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Guide Wire 3
Check Price on Amazon