Guide 3 not found
Husqvarna
Guide wire 3 signal missing
Display shows “Guide 3 not found” on models with a third guide and mower fails to use that path.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Broken guide 3 wire, Loose terminal, Incorrect installation, Station guide 3 output fault
How to Fix / Troubleshooting
Safety first: Disconnect power to the station.
- Check terminal and splices: Ensure guide 3 is correctly connected at the station and spliced into the boundary at the far end.
- Inspect route: Walk the guide 3 path and repair any damage using Husqvarna connectors.
- Test with short loop: Connect a short test wire as guide 3 to verify station output.
- Service station: If no guide 3 signal is present even with a test wire, the charging station may need replacement.
Advertisements
Repair Difficulty
Medium
3/5