E13
Kress Boundary Sensor / Loop Receiver Fault

Robot mower displays E13 and behaves erratically near the boundary; sometimes crosses the wire.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty boundary sensor coil in mower, Damaged sensor cable, Loose connector on main board, Strong electromagnetic interference near boundary

How to Fix / Troubleshooting

Safety first: Turn OFF main power before opening the mower housing.

  • Reduce interference: Ensure no high‑voltage cables, electric fences, or buried power lines run close and parallel to the boundary wire. If they do, reroute the boundary wire further away.
  • Inspect sensor area: The boundary sensor coil is usually located at the front of the mower. Check for physical damage to the front underside and sensor bracket.
  • Check sensor wiring: Open the housing and trace the Boundary Sensor Harness from the front coil to the Main Control Board. Confirm the connector is secure and wires are not cut or pinched.
  • Test in a simple loop: Create a small test loop of boundary wire near the station and see if the mower can detect and follow it. If E13 persists, replace the Boundary Sensor Coil Assembly.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Boundary Sensor Coil Assembly
Check Price on Amazon