Possible Causes
Loose battery pack, Poor contact at battery terminals, Cracked PCB or connector, Worn main switch contacts
How to Fix / Troubleshooting
Safety first: Turn OFF the mower and remove the battery before inspection.
Steps:
- 1. Secure battery: Ensure the battery is firmly held in its compartment and cannot move when the mower bumps.
- 2. Tighten connectors: Check that battery and switch connectors are tight and latch properly.
- 3. Inspect for cracks: Look for cracks in the PCB around heavy components; replace the PCB if found.
- 4. Replace switch: If the main switch feels loose or intermittent, replace it.