F15
Dyson Charge detection or battery temperature sensor fault

Robot shows F15 and may not charge correctly or may shut down when lifted.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty thermistor in battery pack, Damaged battery harness, Corroded battery contacts, Main board charge circuit fault

How to Fix / Troubleshooting

Safety first: Turn the robot OFF and remove it from the dock. Do not use or charge a battery that is hot, swollen, or leaking.

  • Cool‑down: If the robot feels warm, allow it to cool for at least 1 hour before placing it back on the dock.
  • Inspect contacts: Check the battery contacts and dock contacts for corrosion or discoloration. Clean gently with a dry cloth.
  • Reseat or replace battery: If the battery is user‑replaceable, remove and reinstall it. If F15 persists, install a genuine Dyson replacement battery pack.

If a new battery does not resolve F15, the charge sensing circuit on the main board may be defective and requires professional repair.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Battery pack
Check Price on Amazon