F15
Dyson
Charge detection or battery temperature sensor fault
Robot shows F15 and may not charge correctly or may shut down when lifted.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty thermistor in battery pack, Damaged battery harness, Corroded battery contacts, Main board charge circuit fault
How to Fix / Troubleshooting
Safety first: Turn the robot OFF and remove it from the dock. Do not use or charge a battery that is hot, swollen, or leaking.
- Cool‑down: If the robot feels warm, allow it to cool for at least 1 hour before placing it back on the dock.
- Inspect contacts: Check the battery contacts and dock contacts for corrosion or discoloration. Clean gently with a dry cloth.
- Reseat or replace battery: If the battery is user‑replaceable, remove and reinstall it. If F15 persists, install a genuine Dyson replacement battery pack.
If a new battery does not resolve F15, the charge sensing circuit on the main board may be defective and requires professional repair.