E8
Gorenje Vacuum Fan Motor Failure / Overcurrent

Robot vacuum reports E8 or suction fan error; suction is weak or stops completely.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Clogged dustbin or air duct, Blocked HEPA filter, Foreign object in fan housing, Burned‑out suction motor

How to Fix / Troubleshooting

Safety first: Turn the robot OFF and remove the dustbin before inspecting the suction path.

Steps to try:

  • 1. Empty dustbin: Remove and empty the dustbin. Tap it gently to dislodge fine dust.
  • 2. Clean or replace filter: Remove the primary and HEPA filters. Tap them gently outdoors to remove dust. If heavily clogged or older than 3–6 months, replace with Gorenje‑approved filters.
  • 3. Check suction inlet: Inspect the suction opening behind the brush and inside the dustbin compartment for blockages (paper, toys, etc.). Remove any obstructions.
  • 4. Inspect air channels: Use a flashlight to look into the air duct leading to the fan. If you see debris, carefully remove it with a flexible brush.
  • 5. Test suction: Reinstall the bin and filters, power ON, and start a cleaning cycle. Listen for the fan. If it does not spin or E8 returns, the fan motor may be defective.
  • 6. Replace suction module: Replacing the suction fan assembly (motor + housing) is usually required if the motor is burned out or noisy.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Suction Fan Motor Assembly
Check Price on Amazon