Gorenje
Intermittent Power Connection
Robot vacuum occasionally shuts off when going over bumps or when lifted slightly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose battery connector, Cracked solder joints on power switch, Damaged internal wiring harness, Worn main power switch
How to Fix / Troubleshooting
Safety first: Turn OFF the robot and remove it from the dock before opening any covers.
Steps to try:
- 1. Recreate symptom: With the robot ON, gently tap or lift one side a few millimeters. If it shuts off, a loose connection is likely.
- 2. Inspect battery plug: Remove the battery cover and ensure the battery connector is tight and the wires are not strained.
- 3. Check power switch: Wiggle the power switch gently; if the robot turns off/on, the switch may be failing.
- 4. Internal wiring check (advanced): A technician can open the housing and inspect for loose connectors or cracked solder joints on the main PCB.
- 5. Replace faulty component: Replace the battery harness, power switch, or main PCB as indicated by inspection.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Battery Wiring Harness
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements