Hoover Intermittent Power / Logic Reset

Robot vacuum randomly reboots during cleaning without showing an error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose battery connector, Failing battery pack, Overheating main PCB, Firmware instability

How to Fix / Troubleshooting

Safety first: Turn OFF the robot.

  • Check battery connection: Remove the battery cover and ensure the connector is tight and not moving when the robot is shaken gently.
  • Inspect for heat: After a reboot, feel the underside and top of the robot. Excessive heat suggests overheating electronics.
  • Clean vents: Ensure any ventilation slots are not blocked by dust.
  • Firmware update/reset: Update firmware and perform a factory reset.
  • If reboots continue: Replace the battery pack. If that does not help, the main control PCB is likely failing and should be replaced.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon

We may earn a commission from links on this page.